Tables for Selecting Forklifts
To select the right forklift for each hazard class and division location, open the tables below.
- Look in the first column of the table for the hazard class of the material.
- Find the row that has the chemical or substance handled.
- Choose the second or third column based on the division that represents the exposure condition.
Hazard Classification | Acceptable Forklift Designations | |
---|---|---|
Class I: Flammable gases or vapors are or may be present in quantities sufficient for explosion or ignition. | Division I: Condition exists continuously, intermittently, or periodically under normal operating conditions. | Division II: Condition may occur accidentally (e.g., puncture of a storage drum) |
|
Forklift use prohibited. | DY, EE, EX (also DS, ES, GS, LPS) if the only exposure is sealed containers or liquefied or compressed gases in containers. |
|
EX | DY, EE, EX (also DS, ES, GS, LPS) if the only exposure is sealed containers or liquefied or compressed gases in containers. |
Hazard Classification | Acceptable Forklift Designations | |
---|---|---|
Class II: Combustible dust is present. | Division I: Explosive or conductive mixture may be present under normal conditions or where equipment failure can lead to both this condition and arching or sparking. | Division II: Explosive mixture not normally present but where deposits of dust may cause heat rise in electrical equipment. |
|
Forklift use prohibited. | Forklift with electrical enclosures manufacturer approved where magnesium, aluminum or aluminum bronze may be present |
|
EX | Forklift manufacturer approved for this location. |
Other combustible dusts | EX | DY, EE, EX |
Hazard Classification | Acceptable Forklift Designations | |
---|---|---|
Class III: Easily ignitable fibers or flyings are present but not likely to be in suspension in quantities sufficient to ignite. | Division I: Locations in which these materials are handled, manufactured or used | Division II: Locations in which these materials are stored or handled (other than manufacture). |
|
DY, EE, EX | DS, DY, ES, EE, GS, LPS (Type E may continue to be used if used previously at this location.) |