17-3. Personnel Required Qualification/Training.
Demolition and Renovation Activities
- Ensure all employees involved in demolition or renovation are well-informed about the Demolition Plan for safe work conduct.
Load Handling Equipment (LHE) Operators
- LHE Operators must receive proper training and qualification as specified in chapter 16.
Lead Inspectors
- Lead inspectors responsible for conducting surveys must fulfill the training requirements outlined in paragraph 6-3.
Asbestos Inspectors
- Asbestos inspectors conducting surveys are required to meet the training standards specified in paragraph 6-3.
17-4. Roles and Responsibilities.
De-energizing Electrical Components and Service Lines
- The facility owner must identify, verify, and confirm in writing the de-energization of electrical components and service lines to the USACE supervisor/KO or COR and workers before work commencement.
- Provide engineering drawings indicating the location and control means of all service lines to the USACE supervisor/KO or COR.
- Ensure de-energized electrical services are secured using a Lockout/Tagout (LOTO) method and confirm this via field verification as per chapter 12.
Fire Suppression Systems
- The owner must provide written confirmation to the USACE supervisor/KO or COR of the de-activation and chemical removal from the Chemical Fire Suppression (CFS) system before starting renovation or demolition.
- If the CFS system is active after demolition begins, immediately stop work and inform the USACE supervisor/KO or COR.
- Do not abate or remove the CFS system or its components without approval from the USACE supervisor or acceptance by KO or COR.