07.B Lighting Levels.

07.B.01 While work is in progress, offices, facilities, accessways, working areas, construction roads, etc., must be lighted by at least the minimum light intensities specified in Table 7-1.Illumination readings must be taken and recorded whenever proper lighting of an area is in question. A calibrated light meter must be provided, maintained and used as necessary to provide illumination readings.

Facility or Function Lux Foot-candles (lm/ft2)
Accessways
- general indoor
- general outdoor
- exitways, walkways, ladders, stairs

55
33
110

5
3
10
Administrative areas (offices, drafting and meeting rooms, etc.)
540 50
Chemical laboratories 540 50
Construction areas
- general indoor
- general outdoor
- tunnels and general underground work
areas (min 110 lux required at
tunnel/shaft heading during
drilling, mucking, and scaling)

55
33
55

5
3
5
Conveyor routes 110 10
Dam Operating Areas (Interior)
-Tunnels and underground work areas
-Control Stations

55
150

5
15
Docks and loading platforms 33 3
Elevators, freight and passenger 50 5
Temporary Electrical Panels (Interior) 300 30
Temporary Electrical Panels (Exterior) 50 10
First-aid stations and infirmaries 300 30
Maintenance/operating areas/shops
- vehicle maintenance shop
- carpentry shop
- refueling area, outdoors
- shops, fine - medium detail work
- welding shop

300
110
55
540-325
300

30
10
5
50-30
30
Mechanical/electrical equipment rooms 110 10
Outdoor parking areas 33 3
Toilets, wash, and dressing rooms 110 10
Visitor areas 215 20
Warehouses and storage rooms/areas
- indoor rack storage
- outdoor storage

270
33

25
3
Work areas – general (not listed above) 325 30

07.B.02 Office lighting must be a minimum of 50 foot-candles (lm/ft2) or 540 luminance (lx) at the working surface, in accordance with the Illuminating Engineering Society of North America (IESNA) Handbook, RP-1. In office areas, attention must be paid to the control of glare.

07.B.03 Roadway lighting must be in accordance with IESNA RP-8.

07.B.04 Marine lighting must be in accordance with American Bureau of Shipping, Guide for Crew Habitability on Ships.