We're sorry, but OSHAcademy doesn't work properly without JavaScript enabled. Please turn on JavaScript or install a browser that supports Javascript.

904 Oil and Gas Well Inspection
Skip to main content

Retractable Lifelines

Hanger Hardware

Check that hardware used to attach the main body of the retractable lifeline is a positive locking device such as a screw lock carabiner or a 4-part shackle (bolt pin with nut and cotter) attached to an engineered pad eye, an approved strap, or properly installed beam clamp. Confirm that the attachment point is as close to vertical over the work area to prevent swing injuries.

Access Points

Check that the access point is in an area where employees can easily access the device and safely attach their fall protection. It should not be on a ladder where there is no platform.

End Connections

Check that end connections are undamaged, unaltered, and have a double-locking snap hook that moves freely in the eye. If it has one, check if the slip joint indicator shows if the machine has been put under load. If the unit has stopped a fall, or if any other deficiencies are noted with the end connections, take the unit out of service and return it to an approved service center for repair and recertification.

Knowledge Check Choose the best answer for the question.

4-5. What should you do if your self-retracting lifeline unit has stopped a fall, or if any other deficiencies are noted with the end connections?